UGV Chargers 62 kW · Three Views
The displayed renders show a version with optional equipment. The delivered configuration may differ depending on the selected payment terminal, display and other optional equipment.
40 kW DC CHAdeMO + 22 kW AC Type 2
Two different charging ports make it possible to combine DC fast charging with AC charging in one unit.
CHAdeMO · 40 kW
According to the technical specification, the DC port operates within a 150–500 V DC range with an output current of 100 A.
Type 2 · up to 22 kW
The integrated Type 2 AC cable provides up to 22 kW at an output voltage of 400 V AC ±10%.
Installed UGV Chargers Fast Charging Stations
See installed high-power charging stations from UGV Chargers at commercial and public locations.
For Commercial Locations Combining DC and AC Charging
Fuel Stations
A combination of DC and AC charging for different driver needs.
Shopping Centres
Fast DC and AC charging during a visit.
Commercial Car Parks
Two different charging types in one unit.
Corporate Fleets
Managed fleet charging via OCPP.
OCPP 1.6, RFID and Remote Management
The station can be connected to the UGV Chargers software platform for remote management, user authorisation and operation according to the selected business model.
Protection of Both DC and AC Sections
Insulation Monitoring
According to the technical specification, the DC output includes insulation monitoring, overcurrent protection and charging-cable voltage monitoring.
RCD typu B
According to the source specification, the AC output is equipped with a Type B RCD and overcurrent protection.
Input Protection
Overcurrent protection is specified on the AC input side.
Check Available Electrical Capacity Before Installation
Before implementation, check the available electrical capacity, connection method, cable routes and installation location as well as data connectivity. Exact electrical parameters are listed in the Technical Data section below.
Site Analysis
Operation, parking spaces and expected utilisation.
Electrical Capacity
Verification of available grid capacity and connection method.
Installation
Foundation, electrical feed and cable-route preparation.
OCPP and Commissioning
Communication, authorisation and operation setup.
UGV-A62CG-H40T22-RM
Combined UGV Chargers charging station with 40 kW DC + 22 kW AC and two charging ports.
Basic Parameters +
Power Supply and AC Input +
Charging Ports and Outputs +
Communication and Authorisation +
Construction and Dimensions +
Operating Conditions +
Protection Functions +
Optional Equipment +
Standards +
More Fast Charging Stations
Compare other power levels, connectors and configurations of UGV Chargers DC and AC charging stations.
UGV Chargers 62 kW · CHAdeMO + Type 2
Can the Station Be Supplied with a Payment Terminal? +
Does the Station Support OCPP? +
Is the Station Suitable for Outdoor Installation? +
We Will Prepare a Configuration for Your Location
Send us the location type, number of parking spaces, available electrical capacity and the required operating model. UGV Chargers will recommend a suitable configuration according to the technical and operational requirements of the project.