DC + AC Charging Station · 2 Ports

40 kW Charging Station DC CHAdeMO + AC Type 2

Combined UGV Chargers charging station with a total rated power of 62 kW. One CHAdeMO DC port provides 40 kW and the integrated Type 2 AC cable provides up to 22 kW. The station supports OCPP 1.6, RFID and remote management.

62 kW total 40 kW DC 22 kW AC CHAdeMO Type 2 OCPP 1.6 RFID IP54
T
Optional Version with Payment Terminal

On request, the station can be equipped with a touchscreen, integrated payment terminal and camera. The displayed renders show a version with optional equipment.

Request a Quote Technical Data
1 × CHAdeMO · 40 kW DC 1 × Type 2 · 22 kW AC OCPP 1.6 · RFID IP54 · −25 to +50 °C

Model: UGV-A62CG-H40T22-RM

UGV Chargers UGV-A62CG-H40T22-RM – 62 kW DC + AC charging station
UGV Chargers · DC + AC
40 kW DC · 22 kW AC · 2 ports
The displayed version includes optional equipment. Payment terminal, touchscreen and camera are supplied according to the selected configuration.
Configuration

DC and AC Charging in One Floor-Standing Station

Model UGV-A62CG-H40T22-RM combines fast DC charging via CHAdeMO with Type 2 AC charging. It is suitable for managed commercial and public locations where both charging methods are required.

01 / POWER

DC + AC in One Unit

One station combines fast DC charging with AC charging for longer parking periods.

02 / PORTS

Two Different Charging Methods

The configuration is designed for locations that need to serve vehicles using DC CHAdeMO and AC Type 2.

03 / SMART

Ready for Managed Operation

Online management, user authorisation and data connectivity are configured according to the selected operating model.

Station Configuration

UGV Chargers 62 kW · Three Views

The displayed renders show a version with optional equipment. The delivered configuration may differ depending on the selected payment terminal, display and other optional equipment.

UGV Chargers 62 kW – product render, view 1
Product render · view 1
UGV Chargers 62 kW – product render, view 2
Product render · view 2
UGV Chargers 62 kW – product render, view 3
Product render · view 3
Optional Version with Payment Terminal. The displayed renders show a version with optional equipment; the terminal, touchscreen and camera are configured according to the project.
Charging Ports

40 kW DC CHAdeMO + 22 kW AC Type 2

Two different charging ports make it possible to combine DC fast charging with AC charging in one unit.

DC / CHAdeMO

CHAdeMO · 40 kW

According to the technical specification, the DC port operates within a 150–500 V DC range with an output current of 100 A.

Power40 kW DC
Voltage150–500 V DC
Current100 A
Efficiency> 94 %
AC / TYPE 2

Type 2 · up to 22 kW

The integrated Type 2 AC cable provides up to 22 kW at an output voltage of 400 V AC ±10%.

Powerup to 22 kW
Voltage400 V AC ±10 %
Current0–32 A
Configurationintegrated cable
Real Installations

Installed UGV Chargers Fast Charging Stations

See installed high-power charging stations from UGV Chargers at commercial and public locations.

Installed UGV Chargers DC station
Installed UGV Chargers DC station
High-power UGV Chargers station
High-power UGV Chargers station
UGV Chargers charging infrastructure
UGV Chargers charging infrastructure
UGV Chargers DC station in operation
UGV Chargers DC station in operation
Installed UGV Chargers station
Installed UGV Chargers station
Applications

For Commercial Locations Combining DC and AC Charging

FUEL

Fuel Stations

A combination of DC and AC charging for different driver needs.

RETAIL

Shopping Centres

Fast DC and AC charging during a visit.

PARKING

Commercial Car Parks

Two different charging types in one unit.

FLEET

Corporate Fleets

Managed fleet charging via OCPP.

Smart charging

OCPP 1.6, RFID and Remote Management

The station can be connected to the UGV Chargers software platform for remote management, user authorisation and operation according to the selected business model.

Online Operation
Smart charging
UGV Chargers Software
Protection Functions

Protection of Both DC and AC Sections

DC

Insulation Monitoring

According to the technical specification, the DC output includes insulation monitoring, overcurrent protection and charging-cable voltage monitoring.

AC / OUTPUT

RCD typu B

According to the source specification, the AC output is equipped with a Type B RCD and overcurrent protection.

AC / INPUT

Input Protection

Overcurrent protection is specified on the AC input side.

Project and Installation

Check Available Electrical Capacity Before Installation

Before implementation, check the available electrical capacity, connection method, cable routes and installation location as well as data connectivity. Exact electrical parameters are listed in the Technical Data section below.

01

Site Analysis

Operation, parking spaces and expected utilisation.

02

Electrical Capacity

Verification of available grid capacity and connection method.

03

Installation

Foundation, electrical feed and cable-route preparation.

04

OCPP and Commissioning

Communication, authorisation and operation setup.

Technical Data

UGV-A62CG-H40T22-RM

Combined UGV Chargers charging station with 40 kW DC + 22 kW AC and two charging ports.

Basic Parameters +
ManufacturerUGV Chargers
ModelUGV-A62CG-H40T22-RM
Station TypeFloor-standing DC + AC charging station
Total Station Power62 kW (40 kW DC + 22 kW AC)
Number of Charging Ports2 (1 DC + 1 AC)
Power Supply and AC Input +
Grid Connection3P+N+PE / 3P+PEN
Input Voltage400 V AC ±10 %
Input Current99 A
Input Power68 kVA
Frequency50 / 60 Hz
Power Factor at 50% Load> 0.97
Charging Ports and Outputs +
DC portCHAdeMO
DC Power40 kW
DC Output Voltage150–500 V DC
DC Output Current100 A
DC Efficiency> 94 %
AC PortIntegrated Type 2 cable
Maximum AC Power22 kW
AC Output Voltage400 V AC ±10 %
AC Output Current0–32 A
Communication and Authorisation +
OCPP1.6
AuthorisationRFID, mobile applications
Billing According to Source SpecificationBy time / kW depending on the selected solution
ConnectivityEthernet / UMTS 3G / LTE 4G / Wi-Fi
Compatibility Listed in Source SpecificationDSTU EN 61851-1:2014
Construction and Dimensions +
Cabinet Dimensions (W × H × D)600 × 1500 × 500 mm
Overall Dimensions (W × H × D)1100 × 1500 × 600 mm
Protection RatingIP54 · indoor and outdoor installation
Weight in Source Introductory Table190 kg
Weight Listed in the “General” Section215 kg
Operating Conditions +
Operating Temperature−25 to +50 °C
Storage Temperature−25 to +50 °C
Relative Humidity5–95 %, non-condensing
Noise at Full Load< 55 dB
Standby Mode100 W
Anti-Condensation Heater400–415 W
Ventilation165 W
Protection Functions +
DC OutputInsulation Monitoring
DC Output · OvercurrentOvercurrent Protection
DC Charging CableCharging Cable Voltage Monitoring
AC OutputType B residual current device (RCD); overcurrent protection
AC InputOvercurrent Protection
Optional Equipment +
TouchscreenOptional
Payment TerminalOptional
CameraOptional
Standards +
SafetyIEC 61439-2; IEC 62196-2
DC Charging CablesIEC 62196-1:2014; IEC 62196-3:2014
AC Charging CablesEN 62196-1:2014; EN 62196-2:2012 + A11:2013 + A12:2014 + AC:2014
EMCEN 61000-6-2:2005; EN 61000-6-3:2007 + A1:2011
Additional Standards Listed in the Technical SourceDSTU EN 61851-1:2019; DSTU EN 61851-22:2002; DSTU EN 61851-23:2014; DSTU EN 61851-24:2015; DSTU EN 61439-1:2016
Note on the Technical Source: the introductory table lists a weight of 190 kg, while the “General” section lists 215 kg. Before final publication, we recommend confirming the weight of the specific configuration.
UGV Chargers Catalogue

More Fast Charging Stations

Compare other power levels, connectors and configurations of UGV Chargers DC and AC charging stations.

FAQ

UGV Chargers 62 kW · CHAdeMO + Type 2

Can the Station Be Supplied with a Payment Terminal? +
Yes. The payment terminal is optional equipment. The displayed renders show a version with optional equipment; a touchscreen and camera can also be added depending on the project.
Does the Station Support OCPP? +
Yes. The station can be connected to a software platform for remote management and user authorisation.
Is the Station Suitable for Outdoor Installation? +
The technical source lists IP54 and an operating temperature from −25 to +50 °C. The specific installation location should be assessed as part of the project.
DC + AC Project

We Will Prepare a Configuration for Your Location

Send us the location type, number of parking spaces, available electrical capacity and the required operating model. UGV Chargers will recommend a suitable configuration according to the technical and operational requirements of the project.