Model G · floor-standing AC charging station

22 kW AC Charging Station 2 × Type 2 cables

Floor-standing UGV Chargers AC charging station with a total output of 22 kW and two integrated Type 2 cables. Designed for companies, hotels, retail locations, public and commercial car parks, as well as managed parking areas at apartment buildings.

22 kW AC 2 × Type 2 cables 400 V 32 A Mode 3 OCPP RFID / NFC
Request a quote Technical data
✓Floor-standing design ✓IP54 / IK10 ✓Ethernet / Wi-Fi ✓3G / 4G optional

Model: UGV-A22AG-T11T11-R

UGV Chargers floor-standing 22 kW AC charging station with two Type 2 cables
UGV Chargers · Model G
22 kW · 2 × Type 2 cables · OCPP
✓22 kW AC
✓2 charging ports
✓RFID / NFC
✓OCPP
Dual-port Type 2 charging

22 kW AC station with two Type 2 cables

Two integrated Type 2 cables allow vehicles to connect directly to the station without requiring a separate AC cable. The dual-port design is practical for managed parking areas where two vehicles need to charge and parking times are longer.

01 / AC

22 kW total power

Three-phase AC charging with a rated voltage of 400 V and a current of 32 A.

Power22 kW
Voltage400 V
Current32 A
Phases3
02 / TYPE 2

2 × Type 2 cables

Two integrated Type 2 cables simplify everyday use and charging at two parking spaces.

Ports2
Connectors2 × Type 2 cables
ModeMode 3
CurrentAC
03 / SMART

OCPP and RFID

The station supports connection to a software platform via OCPP and user authentication via RFID / NFC.

OCPPyes
RFID / NFCintegrated
Ethernetyes
Wi-Fiyes
Model G

Floor-standing dual-port AC station with 2 × Type 2 cables

Two integrated Type 2 cables are ready for use directly at the station. The floor-standing design is suitable for two adjacent parking spaces at commercial and managed locations.

UGV Chargers UGV-A22AG-T11T11-R – floor-standing AC station with two Type 2 cables
Two parking spaces

No separate charging cable required

Vodič pripojí kompatibilný elektromobil priamo pomocou the integrated Type 2 cable. The station has two charging ports and a total rated output of 22 kW.

Power22 kW total
Ports2
Cables2 × Type 2
Designfloor-standing
Dimensions1265 × 430 × 195 mm
Weight35 kg
Applications

Where is a floor-standing 22 kW AC station suitable?

It is suitable for locations where electric vehicles remain parked for longer and the operator needs managed AC charging.

OFFICE

Companies and offices

Charging for employees, company vehicles and visitors.

HOTEL

Hotels

AC charging during a guest's stay or overnight parking.

PARKING

Commercial car parks

Managed charging point with OCPP and RFID authentication.

RESIDENTIAL

Apartment buildings

Solution for shared or commercially managed parking.

Smart charging

OCPP, RFID and remote management

The station can be connected to a software platform via the OCPP protocol. Depending on the selected solution, the operator can manage users, charging sessions, tariffs and station operation.

✓
OCPP. Connection to a managed charging network.
✓
RFID / NFC. Authentication of authorised users.
✓
Ethernet / Wi-Fi. Standard data connectivity.
✓
3G / 4G. Available as an optional configuration.
Station management
Type 2 + OCPP + RFID
OCPPsupported
RFID / NFCintegrated
Ethernet / Wi-Fiyes
3G / 4Goptional
Discuss your solution
Construction and protection

Floor-standing design for managed locations

Oceľový vandaloodolný kryt, LED indication, IP54 protection and IK10 mechanical resistance support everyday station operation in commercial environments.

IP54

Protection rating

IP54 according to IEC 60529, based on the supplied technical specification.

IK10

Mechanical resistance

IK10 according to IEC 62262.

STEEL

Steel enclosure

Vandal-resistant floor-standing design.

LED

LED indication

Visual indication of station operating states.

Installation

Check the site and electrical supply before installation

Selection of protection and the supply cable must always be based on the specific project, cable route length and installation method and local conditions. The data below is taken from the supplied technical documentation.

01

Location

The floor-standing design requires a prepared site and a solid mounting foundation.

02

Electrical supply

The designer verifies available power, protection, cable cross-section and installation method.

03

OCPP and internet

Online operation requires suitable data connectivity.

Technical data

UGV-A22AG-T11T11-R

Floor-standing AC charging station UGV Chargers 22 kW with two integrated Type 2 cables.

Basic parameters +
ManufacturerUGV Chargers
ModelUGV-A22AG-T11T11-R
Model versionModel G
Station typeFloor-standing AC charging station
Current typeAC
Rated power22 kW total
Rated voltage400 V
Current32 A
Number of phases3
Charging modeMode 3
Mounting typeFloor-standing installation
Charging ports and connectors +
Number of charging ports2
Port type2 × integrated Type 2 cables
Connector typeType 2
Total station power22 kW
Charging modeAC / Mode 3
Communication and authentication +
OCPPSupported
RFID / NFCIntegrated module
EthernetYes
Wi-FiYes
IndicationLED indication of operating modes
Construction and dimensions +
EnclosureSteel, vandal-resistant design
Dimensions (H × W × D)1265 × 430 × 195 mm
Weight35 kg
Protection ratingIP54 according to IEC 60529
Mechanical resistanceIK10 according to IEC 62262
Operating conditions +
Operating temperature−30 to +50 °C
Storage temperature−30 to +50 °C
Relative humidity5–95 %
Optional equipment +
3G / 4G communicationOptional
Video cameraOptional
Leakage current protectionOptional
Standards and compliance +
Protection ratingIP54 according to IEC 60529
Mechanical resistanceIK10 according to IEC 62262
Charging modeMode 3
UGV Chargers Catalogue

Other AC and DC Charging Stations

Compare other UGV Chargers configurations for commercial and managed locations.

FAQ

22 kW AC Charging Station with 2 × Type 2 Cables

Which connectors does model UGV-A22AG-T11T11-R use? +
The station has two integrated Type 2 cables and two charging ports.
What power does the station provide? +
The total rated station power is 22 kW at 400 V and 32 A in a three-phase configuration.
Does the station support OCPP? +
Yes. The station can be connected to a software platform via OCPP for remote management of commercial operation.
Does the station support RFID? +
Yes. The technical documentation specifies an integrated RFID / NFC module for user authentication.
Is 3G / 4G connectivity standard equipment? +
No. According to the supplied specification, 3G / 4G is available as an option. Ethernet and Wi-Fi are included in the standard configuration.
Quotation

Looking for a floor-standing 22 kW AC charging station?

Send us the location type and number of parking spaces and the available electrical capacity. UGV Chargers will recommend a suitable configuration and operating model.