DC + AC Fast Charging Station · 4 Ports

80 kW DC Fast Charging Station + 22 kW AC · 4 Ports

Commercial UGV Chargers charging station with a total rated power of 102 kW: 80 kW DC and 22 kW AC. The configuration combines three DC ports CCS Combo 2, CHAdeMO and GB/T with an integrated Type 2 cable for AC charging.

80 kW DC 22 kW AC CCS2 CHAdeMO GB/T Type 2 OCPP 1.6 IP54
Request a Quote Technical Data
✓3 DC + 1 AC port ✓CCS2 · CHAdeMO · GB/T · Type 2 ✓OCPP 1.6 · RFID ✓IP54 · −25 to +50 °C

Model: UGV-A102CG-H50C80G80T22-D-RMH

UGV Chargers UGV-A102CG-H50C80G80T22-D-RMH – 80 kW DC + 22 kW AC
UGV Chargers · DC + AC
80 kW DC · 22 kW AC · 4 ports
✓102 kW total
✓3 DC + 1 AC
✓CCS2 / CHAdeMO / GB/T / Type 2
✓Ethernet / 3G / 4G / Wi-Fi
Configuration

80 kW DC + 22 kW AC in One Charging Station

Model UGV-A102CG-H50C80G80T22-D-RMH combines three DC charging standards and one Type 2 AC port. It is designed for commercial and public locations where broader vehicle compatibility is required.

01 / POWER

102 kW total

The 80 kW DC section is complemented by a separate AC port rated up to 22 kW.

DC power80 kW
AC power22 kW
Total power102 kW
Ports4 (3 DC + 1 AC)
02 / PORTS

Four Charging Ports

Three DC connectors and an integrated Type 2 cable for AC charging.

DC 1CCS Combo 2
DC 2CHAdeMO
DC 3GB/T
ACType 2 · 22 kW
03 / SMART

OCPP 1.6 and RFID

Online management, user authorisation and data connectivity according to the project.

OCPP1.6
AuthorisationRFID / mobile applications
ConnectivityEthernet / 3G / 4G / Wi-Fi
Protection ratingIP54
Charging Ports

CCS2, CHAdeMO, GB/T and Type 2

Four ports cover three DC standards and Type 2 AC charging. The 80 kW value represents the total power of the DC section, not the power of each DC port.

DC / CCS2

CCS Combo 2

Voltage150–1000 V DC
Currentup to 220 A peak
DC / CHAdeMO

CHAdeMO

Voltage150–500 V DC
Current125 A
DC / GB/T

GB/T

Voltage150–1000 V DC
Currentup to 250 A peak
AC / TYPE 2

Type 2

Powerup to 22 kW
Voltage400 V AC ±10 %
Current0–32 A
DC Parameters

80 kW Shared DC Power

The technical source specifies efficiency above 94% and a power factor above 0.97 at 50% load.

Configuration
3 DC + 1 AC
DC power80 kW
AC power22 kW
Efficiency> 94 %
Power factor> 0.97
Dynamic Power Distribution

80 kW DC Adapts to Active DC Ports

During simultaneous DC charging, the system can distribute available power between CCS2, CHAdeMO and GB/T according to current vehicle demand and the station configuration. The Type 2 AC port is a separate part of the configuration.

Available DC Section Power 80 kW DC
80 kW DC
CCS2 80 kW
active charging
CHAdeMO 0 kW
port ready
GB/T 0 kW
port ready
↔ Illustrative animation of the DC dynamic power distribution principle. The displayed values are examples; actual power depends on connected vehicles and the system configuration.
1 DC VEHICLE

Power for the Active Port

Available DC power is used according to the current demand of the connected vehicle.

2–3 VEHICLES

Continuous Redistribution

With multiple vehicles, power can be distributed between the active DC ports.

AC PORT

Type 2 up to 22 kW

The Type 2 AC port is a separate part of the station configuration.

Real Installations

Installed UGV Chargers Fast Charging Stations

See installed high-power charging stations from UGV Chargers at commercial and public locations.

Installed UGV Chargers fast charging station
Installed UGV Chargers DC station
Installed UGV Chargers fast charging station at a commercial location
High-power UGV Chargers station
Installed UGV Chargers DC charging station
UGV Chargers charging infrastructure
UGV Chargers DC station in operation
UGV Chargers DC station in operation
High-power UGV Chargers charging station
Installed UGV Chargers station
Applications

For Commercial Locations Serving Different EV Types

The combination of three DC standards and Type 2 is suitable where the operator needs to support a broader range of vehicles.

01

Fuel Stations

DC charging for transit and regional traffic.

02

Shopping Centres

DC and AC charging during a visit.

03

Commercial Car Parks

Multiple charging standards in one unit.

04

Corporate Fleets

Managed vehicle charging with online management via OCPP.

Smart Charging

OCPP 1.6, RFID and Remote Management

The station supports OCPP 1.6 and can be connected to a software platform for online management. The technical source lists RFID, mobile applications and billing according to time or energy, depending on the operator's selected solution.

✓
OCPP 1.6. Integration into a managed charging network.
✓
RFID. User authorisation directly at the station.
✓
Mobile App. User access through the software solution.
✓
Ethernet / 3G / 4G / Wi-Fi. Multiple data connectivity options.
Online Operation
DC + OCPP 1.6
OCPP 1.6
RFID yes
Mobile applications supported
Connectivity Ethernet / 3G / 4G / Wi-Fi
UGV Chargers Software
Protection Functions

Protection for Both DC and AC Outputs

DC / OUTPUT

Insulation Monitoring

The technical source lists insulation monitoring on the DC output.

AC / OUTPUT

Residual Current Protection

The technical source lists a residual current device (RCD) on the AC output.

Project and Installation

Check Available Electrical Capacity Before Installation

The station requires a technical assessment of the electrical connection, cable routes, installation location, data connectivity and the operating model of the charging location.

01 / GRID

400 V AC

Input 3P+N+PE / 3P+PEN, 169 A and 111 kVA according to the technical source.

02 / SITE

Floor-Standing Design

Overall dimensions 1100 × 2200 × 700 mm, weight 260 kg.

03 / DATA

Online Connectivity

Ethernet, UMTS 3G, LTE 4G or Wi-Fi depending on the project.

Technical Data

UGV-A102CG-H50C80G80T22-D-RMH

Combined UGV Chargers fast charging station with 80 kW DC + 22 kW AC and four charging ports.

Basic Parameters +
ManufacturerUGV Chargers
ModelUGV-A102CG-H50C80G80T22-D-RMH
Station TypeFloor-standing DC + AC fast charging station
Total Station Power102 kW (80 kW DC + 22 kW AC)
DC power80 kW
AC power22 kW
Number of Charging Ports4 (3 DC + 1 AC)
Power Supply and AC Input +
Grid Connection3P+N+PE / 3P+PEN
Input Voltage400 V AC ±10 %
Input Current169 A
Input Power111 kVA
Frequency50 / 60 Hz
Power Factor at 50% Load> 0.97
Charging Ports and Outputs +
DC port 1CCS Combo 2 · 150–1000 V DC · up to 220 A peak
DC port 2CHAdeMO · 150–500 V DC · 125 A
DC port 3GB/T · 150–1000 V DC · up to 250 A peak
AC portIntegrated Type 2 cable · up to 22 kW
AC Output Voltage400 V AC ±10 %
AC Output Current0–32 A
DC Efficiency> 94 %
Dynamic Power Distribution +
DC Power ManagementDynamic distribution of available DC power between active DC ports
Total Available DC Power80 kW
PrinciplePower adapts to the current demand of connected vehicles and the system configuration
AC portType 2 up to 22 kW is a separate part of the configuration
Communication and Authorisation +
OCPP1.6
AuthorisationRFID, mobile applications
Billing According to SourceBy time / kW
ConnectivityEthernet / UMTS 3G / LTE 4G / Wi-Fi
Construction and Dimensions +
Cabinet Dimensions (W × H × D)600 × 2000 × 600 mm
Overall Dimensions (W × H × D)1100 × 2200 × 700 mm
Weight260 kg
Protection RatingIP54
Operating Conditions +
Operating Temperature−25 to +50 °C
Storage Temperature−25 to +50 °C
Relative Humidity5–95%, non-condensing
Noise at Full Load< 55 dB
Standby Mode100 W
Anti-Condensation Heater600 W
Ventilation300 W
Protection Functions +
DC OutputInsulation Monitoring
AC OutputResidual Current Protection (RCD)
Standards +
SafetyIEC 61439-2; IEC 62196-2
EMCEN 61000-6-2:2005; EN 61000-6-3:2007 + A1:2011
Additional Standards Listed in the Technical SourceDSTU EN 61851-1:2019; DSTU EN 61851-22:2002; DSTU EN 61851-23:2014; DSTU EN 61851-24:2015; DSTU EN 61439-1:2016
Compatibility Listed in the SourceDSTU EN 61851-1:2014
UGV Chargers Catalogue

More DC Fast Charging Stations

Compare other power levels, connectors and configurations of UGV Chargers DC charging stations.

FAQ

80 kW DC + 22 kW AC Fast Charging Station

How Many Ports Does the Station Have?+
Model UGV-A102CG-H50C80G80T22-D-RMH has four ports: CCS Combo 2, CHAdeMO, GB/T and AC Type 2.
Is 80 kW the Power of Each DC Port?+
No. In the technical source, 80 kW is specified as the power of the DC section. It is therefore not presented as guaranteed independent power for each DC connector.
What Power Does the Type 2 AC Port Provide?+
According to the technical source, the integrated Type 2 cable has a maximum power of 22 kW, 400 V AC ±10% and 0–32 A.
How Does Dynamic Power Distribution Work?+
Available DC power can be redistributed between active DC ports according to the demand of connected vehicles and the system configuration.
Does the Station Support OCPP?+
Yes. The technical specification lists OCPP 1.6, RFID, mobile applications and Ethernet / 3G / 4G / Wi-Fi.
Is the Station Suitable for Outdoor Installation?+
The technical source lists IP54 and an operating temperature from −25 to +50 °C. The specific installation location should be assessed as part of the project.
DC + AC Project

Planning an 80 kW DC + 22 kW AC Charging Station?

Send us the location type and number of parking spaces and the available electrical capacity. UGV Chargers will assess the site's technical conditions and prepare a suitable configuration for your project.