DC + AC charging station · 4 ports

240 kW DC Fast Charging Station 2 × CCS2 + Type 2 + Type 1

Multi-port UGV Chargers charging station with 240 kW DC power and two AC ports rated at 22 kW and 7 kW. The total rated power of this configuration is 269 kW. Four charging ports in one unit support vehicles using CCS Combo 2, Type 2 and Type 1.

269 kW total 240 kW DC 2 × CCS2 Type 2 · 22 kW AC Type 1 · 7 kW AC OCPP 1.6 RFID
Request a Quote Technical Data
✓2 × CCS Combo 2 ✓Type 2 · 22 kW AC ✓Type 1 · 7 kW AC ✓IP54 · OCPP 1.6

Model: UGV-A269CG-C240C240T22J7-D-RMH

UGV Chargers UGV-A269CG-C240C240T22J7-D-RMH 240 kW DC fast charging station
UGV Chargers · DC + AC
240 kW DC · 22 + 7 kW AC · 4 ports
✓240 kW DC total
✓2 DC + 2 AC ports
✓150–1000 V DC
✓Ethernet / 3G / 4G / Wi-Fi
Configuration

240 kW DC + Two AC Ports in One Charging Station

The model combines two CCS Combo 2 DC ports with an integrated Type 2 AC cable and an integrated Type 1 AC cable. According to the technical specification, the total rated power is 269 kW: 240 kW DC + 22 kW AC + 7 kW AC.

01 / DC

240 kW DC · 2 × CCS2

The DC section provides a total rated power of 240 kW across two CCS Combo 2 charging ports.

DC power240 kW total
DC ports2 × CCS2
Voltage150–1000 V DC
Currentup to 500 A peak
02 / AC

Type 2 + Type 1

Two integrated AC cables complement fast DC charging: 22 kW Type 2 and 7 kW Type 1.

Type 222 kW AC
Type 2 voltage400 V AC ±10%
Type 17 kW AC
Type 1 voltage230 V AC ±10%
03 / GRID

Grid Connection

The project should verify available electrical capacity, connection method and the technical conditions at the location.

Connection3P+N+PE / 3P+PEN
Voltage400 V AC ±10%
Input current462 A
Input power290 kVA
Model UGV-A269CG

Four Charging Ports in One Floor-Standing Solution

The station combines fast DC charging via two CCS2 connectors with two integrated AC cables: Type 1 and Type 2.

UGV Chargers 240 kW DC station with 2 CCS2, Type 1 and Type 2 – front view
Front view · 2 × CCS2 + Type 1 + Type 2
UGV Chargers 240 kW DC station with 2 CCS2, Type 1 and Type 2 – side view
Side view · DC + AC configuration
4 Charging Ports

DC and AC Charging at One Location

This combined solution allows the operator to provide fast DC charging and separate AC charging ports in one unit.

✓
Port 1 · CCS Combo 2. DC · 150–1000 V · up to 500 A peak.
✓
Port 2 · CCS Combo 2. DC · 150–1000 V · up to 500 A peak.
✓
Port 3 · Type 2 cable. AC · up to 22 kW · 400 V ±10% · 0–32 A.
✓
Port 4 · Type 1 cable. AC · up to 7 kW · 230 V ±10% · 0–32 A.
Total Configuration
240 kW DC + 22 kW + 7 kW AC
Total power269 kW
DC ports2 × CCS2
AC portsType 2 + Type 1
Number of ports4
Discuss This Configuration
Dynamic Power Distribution

240 kW DC Is Dynamically Distributed Between Two CCS2 Ports

The DC section operates with a total available power of 240 kW. This power can be dynamically redistributed between the two CCS Combo 2 connectors according to the current demand of connected vehicles and the system configuration. The 22 kW Type 2 and 7 kW Type 1 AC ports are separate parts of this configuration.

Available DC Section Power 240 kW DC
240 kW DC
UGV Chargers
CCS2 · Port 1 240 kW
active charging
CCS2 · Port 2 0 kW
port ready
Type 222 kW AC
Type 17 kW AC
↔ Illustrative animation of the DC dynamic power distribution principle. The displayed values are examples. Actual power at each CCS2 port depends on vehicle demand and the system configuration.
01 / 1 VEHICLE

Power for the Active CCS2 Port

If only one DC port is active, power does not need to remain permanently reserved for the unused second CCS2 connector.

02 / 2 VEHICLES

Power Is Distributed According to Demand

When two vehicles charge simultaneously, the system continuously adjusts distribution of the available 240 kW between both CCS2 ports.

03 / DC + AC

DC and AC in One Charging Station

Dynamic distribution applies to the DC section with two CCS2 ports. The Type 2 and Type 1 AC ports remain separate parts of the configuration.

Real Installations

Installed UGV Chargers Fast Charging Stations

See installed high-power UGV Chargers charging stations at commercial and public locations.

Installed UGV Chargers fast charging station
Installed UGV Chargers DC station
Installed UGV Chargers fast charging station at a commercial location
High-power UGV Chargers station
Installed UGV Chargers DC charging station
UGV Chargers charging infrastructure
UGV Chargers DC charging station in operation
UGV Chargers DC station in operation
High-power UGV Chargers charging station
Installed UGV Chargers station
Applications

For Locations That Need Fast DC and AC Charging

A combination of DC and AC ports can fit locations serving different vehicle types and different parking durations.

FUEL

Fuel Stations

Fast DC charging combined with AC ports at one location.

RETAIL

Shopping Centres

Multiple charging options for visitors with different dwell times.

PARKING

Public Car Parks

Four ports in one unit for managed charging locations.

FLEET

Corporate Fleets

DC and AC options for vehicles using different charging standards.

Smart Charging

OCPP 1.6, RFID and Remote Management

The station supports OCPP 1.6 and can be connected to a software platform for online management. The technical source lists RFID, mobile applications and billing according to time or energy, depending on the operator's selected solution.

✓
OCPP 1.6. Integration into a managed charging network.
✓
RFID. User authorisation directly at the station.
✓
Mobile app. User access through the software solution.
✓
Ethernet / 3G / 4G / Wi-Fi. Multiple data connectivity options.
Online Operation
DC + AC + OCPP 1.6
OCPP1.6
RFIDyes
Mobile applicationssupported
ConnectivityEthernet / 3G / 4G / Wi-Fi
UGV Chargers Software
Protection Functions

Protection for Both DC and AC Charging Sections

The technical specification lists separate protection functions for the DC and AC outputs.

DC / OUTPUT

DC Side

✓
Insulation monitoring on the DC output.
AC / OUTPUT

AC Side

✓
Residual current protection / protective shutdown device (RCD).
Project and Installation

A Combined DC + AC Station Requires a Technical Site Assessment

Before implementation, verify available electrical capacity, connection method, installation location, cable routes, parking spaces and data connectivity.

01

Site Analysis

Number of spaces, traffic flow and planned utilisation.

02

Electrical Capacity

Verification of the 400 V supply and available grid capacity.

03

Installation

Foundation, electrical feeds and cable-route preparation.

04

OCPP and Operation

Connectivity, authorisation and software-management setup.

Technical Data

UGV-A269CG-C240C240T22J7-D-RMH

Combined UGV Chargers charging station: 240 kW DC + 22 kW AC + 7 kW AC.

Basic Parameters +
ManufacturerUGV Chargers
ModelUGV-A269CG-C240C240T22J7-D-RMH
TypeFloor-standing DC + AC charging station
Total power269 kW
DC power240 kW total
AC power22 kW + 7 kW
Number of ports4 (2 DC + 2 AC)
Cabinet dimensions (W × H × D)800 × 2000 × 800 mm
Overall dimensions (W × H × D)1300 × 2200 × 870 mm
Weight600 kg
AC Input +
Grid connection3P+N+PE / 3P+PEN
Input voltage400 V AC ±10%
Input current462 A
Input power290 kVA
Frequency50 / 60 Hz
Power factor at 50% load> 0.97
DC Ports +
DC port 1CCS Combo 2
DC port 2CCS Combo 2
Station DC power240 kW total
Output voltage150–1000 V DC
Output currentup to 500 A peak on the listed DC port
Efficiency> 94%
AC Ports +
AC port 1Integrated Type 1 cable
Max. Type 1 power7 kW
Type 1 voltage230 V AC ±10%
Type 1 current0–32 A
AC port 2Integrated Type 2 cable
Max. Type 2 power22 kW
Type 2 voltage400 V AC ±10%
Type 2 current0–32 A
Operating Conditions +
Operating temperature−25 to +50 °C
Storage temperature−25 to +50 °C
Relative humidity5–95%, non-condensing
Protection ratingIP54
Maximum dimensions (W × H × D)1300 × 2200 × 870 mm
Weight600 kg
Noise at full load< 55 dB
Station Own Consumption +
Standby mode100 W
With anti-condensation heater on600 W
With ventilation on300 W
Dynamic Power Distribution +
DC power managementdynamic distribution of available power between two CCS2 ports
Principlepower adapts to the current demand of connected vehicles and the system configuration
Total DC power240 kW
AC portsType 2 22 kW and Type 1 7 kW are separate parts of the configuration
Communication and Authorisation +
OCPP1.6
AuthorisationRFID, mobile applications
Billingby time / kWh depending on the selected solution
ConnectivityEthernet / UMTS 3G / LTE 4G / Wi-Fi
Compatibility listed in sourceDSTU EN 61851-1:2014
Protection Functions +
DC outputinsulation monitoring
AC outputresidual current protection / protective shutdown device (RCD)
Standards Listed in the Technical Specification +
SafetyIEC 61439-2; IEC 62196-2
EMCEN 61000-6-2:2005; EN 61000-6-3:2007 + A1:2011
Additional standards in sourceDSTU EN 61851-1:2019; DSTU EN 61851-22:2002; DSTU EN 61851-23:2014; DSTU EN 61851-24:2015; DSTU EN 61439-1:2016
Request a Quote
UGV Chargers Catalogue

More DC Fast Charging Stations

Compare other power levels, connectors and configurations of UGV Chargers DC charging stations.

FAQ

240 kW DC + AC Fast Charging Station

What Is the Total Power of This Configuration? +
According to the technical specification, the total rated power is 269 kW: 240 kW DC + 22 kW AC + 7 kW AC.
How Many Charging Ports Does the Station Have? +
The station has four ports: 2 × CCS Combo 2 for DC charging, 1 × integrated Type 2 cable rated up to 22 kW and 1 × integrated Type 1 cable rated up to 7 kW.
Does Each CCS2 Port Provide 240 kW? +
In the supplied technical source, 240 kW is specified as the total power of the DC section with two CCS2 ports. It is therefore not presented as guaranteed independent power for each individual port.
What Is the DC Voltage Range? +
The technical specification lists a 150–1000 V DC range for both CCS Combo 2 ports.
How Does Dynamic Power Distribution Work? +
The total 240 kW DC can be dynamically distributed between the two CCS2 ports according to the current demand of connected vehicles and the system configuration. The 22 kW Type 2 and 7 kW Type 1 AC ports are separate parts of the configuration.
Does the Station Support OCPP? +
Yes. The technical source lists OCPP 1.6, RFID, mobile applications and data connectivity via Ethernet, 3G, 4G or Wi-Fi.
Is the Station Suitable for Outdoor Installation? +
The technical specification lists IP54, an operating temperature from −25 to +50 °C and indoor/outdoor use. The specific installation location should be assessed during project design.
DC + AC Project

Need to Combine Fast DC and AC Charging?

Send us the location type, number of parking spaces and available electrical capacity. UGV Chargers will assess the technical conditions and prepare a suitable configuration for your project.